Zuo Shi PingIndustrial Supplier Directory

IEC 62552 Two Stations Refrigerator Energy Efficiency Test System

IEC 62552 Two Stations Refrigerator Energy Efficiency Test System

Overview

IEC 62552 Two Stations Refrigerator Energy Efficiency Test System supplied by Sinuo Testing Equipment Co. , Limited. Key published specifications: Temperature Adjust/Control; Humidity Adjust/Control; Applied Standards IEC 62552,etc.; Temperature Range 0°C To +50°C ±0.3°C. Contact the supplier through the RFQ form for pricing, lead time and full datasheets.

Technical specifications

TemperatureAdjust/Control
HumidityAdjust/Control
Applied StandardsIEC 62552,etc.
Temperature Range0°C To +50°C ±0.3°C
Humidity Range35%RH To 93%RH ± 3.0%RH
Test Capacity Range210L~550L
Control MethodComputer & Software
Output Power5KVA
Compliance StandardsIEC 62552:2015
Laboratory StructureB1-grade 100mm thick polyurethane foam insulation panels
External dimensions4000mm W * 4000mm D * 3200mm H
Performance ParametersTemperature range: 0°C to +50°C ±0.3°C
Wind speedless than 0.25 m/s
Vertical temperature gradientless than 0.88°C/m
Temperature & Humidity ControlTemperature controller: SR93
Temperature controllerSR93
Control range0°C to 50°C
Control accuracy±0.3°C
Humidity control range35% to 95% RH
Humidity control accuracy±3% RH
Measurement accuracy±0.3°C (-5°C to 80°C)
Temperature parameter acquisitionYokogawa GM10, 40 channels
Control SystemTemperature and humidity controller: SR93
Temperature and humidity controllerSR93
Programmable logic controllerMitsubishi PLC
Construction & MaterialsStainless steel air handling cabinet (≥1.0mm thickness)