COMBIVERT T6 Auxiliary Inverter

Overview
COMBIVERT T6 Auxiliary Inverter supplied by KEB America. Key published specifications: HV DC link rated voltage range 520 … 750 VDC; HV DC link input voltage range 200 … 820 VDC; Nominal DC Input Current 120 A; Maximum DC Input Current (60 sec.) 180 A. Contact the supplier through the RFQ form for pricing, lead time and full datasheets.
Technical specifications
| HV DC link rated voltage range | 520 … 750 VDC |
|---|---|
| HV DC link input voltage range | 200 … 820 VDC |
| Nominal DC Input Current | 120 A |
| Maximum DC Input Current (60 sec.) | 180 A |
| Continuous Electrical Power | 60 kW |
| Maximum Electrical Power (60 sec.) | 90 kW |
| LV DC Voltage Supply Range | 9 … 32 VDC |
| Cooling Type | Liquid Cooling |
| Coolant Temperature | 30 … 60 °C |
| Coolant Flow Rate | 5 … 15 l/min |
| Maximum Coolant System Pressure | 2 bar |
| Type Approvals | CE, E1 |
| Protection | ISO20653 6K9K /DIN EN 60529 67 |
| Operating Temperature | -30 … +70 °C |
| Motor Control | Sensorless Closed Loop, V/Hz |
| Control Types | Velocity, Position |